HAWKE 501/453/UNIVERSAL CABLE GLANDS
HAWKE铠装防爆格兰(501/453/UNIV系列)HAWKE代理商:上海颐品自动化科技有限公司Hazardous Area Cable Glands from
HawkeHawke 501/453/Universal cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables. Mainly used with cables that show ‘cold flow’ characteristics.Hawke 501/453/Universal cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 Gas Groups IIA, IIB and IIC, 3.5-91.6mm outside cable diameters.When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box. Exdb IIC Gb, Exeb IIC Gb, ExnR IIC Gc, Extb IIIC Db Aromoured Cables ATEX & IECEx Cable Gland.Hawke 501/453/Universal cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.- Flameproof Exdb
- Increased Safety Exeb
- Restricted Breathing ExnR
- Dust Extb
- Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx
HAWKE 501/453/UNIVERSAL CABLE GLAND TECHNICAL SPECIFICATION
- Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, ExnR IIC Gc, Extb IIIC Db
- Certificate No’s – Baseefa06ATEX0057X and IECEx BAS 06.0014X
- Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 Gas Groups IIA, IIB /li>
- Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31
- Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X
- Deluge Protection – DTS01
- Operating Temperature Range -60°C to +80°C
CABLE GLAND the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6). Note: If the equipment has a threaded entry, it may be advisable to screw the entry component into the equipment to prevent twisting of the cable after step D
Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.
Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.
- 501/421 Cable Gland Unarmoured – outer cable sheath cable sealing
- 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath
- 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas
- ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 Gas Groups IIA, IIB and IIC hazardous areas
- ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 Gas Groups IIA, IIB and IIC hazardous areas
Hawke防爆格兰(Hawke Cable Gland-上海颐品自动化)
Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II
Hawke防爆格兰代理商:上海颐品自动化科技有限公司
关键词:Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀,Hawke防爆接线盒,Hawke防爆控制箱
Hawke防爆格兰等产品规格书及相关证书-请咨询上海颐品自动化科技有限公司